Model MultiEX 016 · benchtop 16-sample extractor

Compact benchtop nucleic acid extraction for 1–16 samples per run

Magnetic-bead automation on 96-deep well plates · 7-inch touchscreen · optional 24V battery · open-system kits (confirm kit IFU)

  • 1–16 samples per run on 96-deep well plates
  • 50–1000 µL processing volume · 37°C to 125°C heating
  • Optional field battery · built-in UV sterilization (vendor-stated)

Key Specifications

Model MultiEX 016
Throughput 1–16 samples per run
Processing volume 50–1000 µL
Footprint 210 × 250 × 315 mm · 9 kg

Why labs evaluate the MultiEX 016

Molecular, clinical, and research labs that run smaller batches need a benchtop nucleic acid extractor without dedicating a full high-throughput line. The MultiEX 016 processes 1–16 samples per run on a 96-deep well plate with magnetic-bead separation.

Manufacturer specifications list 50–1000 µL processing volume, heating from 37°C to 125°C, eight mixing levels, and stirring up to 10 Hz. An auto-check function verifies plate and magnetic rod positioning before a run.

The open-system design supports magnetic-bead kits from multiple suppliers — confirm compatibility with your kit instructions for use (IFU) before validation.

  • Throughput-fit automation
  • Magnetic-bead workflow clarity
  • Quote-first purchase path
Workflow fit
Automated bind, wash, and elute on vendor-specified plate formats.
Kit approach
Open-system magnetic-bead kits — confirm kit IFU before validation.
Buying path
Purchase inquiry with throughput, sample type, and volume class details.

More MultiEX 016 photos

  • MultiEX 016 benchtop nucleic acid extractor — alternate front angle with touchscreen visible
  • MultiEX 016 automated extractor — side profile on laboratory bench
  • MultiEX 016 nucleic acid extraction system — close-up of instrument housing and controls

1–16 samples per run

Throughput fits startup batches, teaching labs, and mobile or field programs that do not need a full 96-sample instrument.

Compact footprint

210 × 250 × 315 mm footprint and 9 kg weight support bench placement where space is limited.

Optional battery operation

24V DC with included 100–240V adapter; optional 24V 5A external battery for field-deployable setups (vendor-stated).

Protocol control on-device

Create, edit, and delete protocols; store more than 500 programs; import and export via 2× USB ports.

Match 16-sample throughput to your batch size before you compare larger MultiEX tiers — submit a purchase inquiry for kit fit and availability.

Key features

  • Magnetic bead-based separation
  • 1–16 samples per run
  • 96-deep well plate (conical / round bottom)
  • 50–1000 µL processing volume
  • Heating 37°C to 125°C
  • 8 adjustable mixing levels · up to 10 Hz stirring
  • Auto-check for plate and magnetic rod positioning
  • 7-inch color touchscreen
  • Built-in UV sterilization (vendor-stated)
  • Open-system magnetic-bead kits (confirm kit IFU)
  • Optional 24V 5A external battery
  • 2× USB program import/export
  • Noise under 55 dB (vendor-stated)

Ideal applications

Priority 01

Startup & growing labs

Challenge: First automated extraction platform with limited bench space and budget.

Value: Entry throughput tier with full numeric specs for evaluation and purchase planning.

Priority 02

Field & mobile programs

Challenge: Power and portability for on-site nucleic acid prep.

Value: Compact unit with optional battery — confirm deployment requirements during inquiry.

Priority 03

Research & teaching

Challenge: Mid-low batch sizes with protocol flexibility.

Value: On-device program management and open-system reagent path (confirm kit IFU).

What's in the box

Typical shipment includes core instrument and power — confirm accessories with your specialist.

  • MultiEX 016 extractor
  • 100–240V AC adapter
  • User manual
  • 7-inch touchscreen (integrated)
  • UV disinfection (integrated)
  • 24V 5A battery (Optional)
  • Magnetic bead reagent kit (Optional)
  • 96-deep well plates (Optional)

Technical specs and compatibility

Designed for fast technical review. Final compliance and warranty wording remains marked until approved documentation is published.

Model / SKU MultiEX 016
Throughput 1–16 samples per run
Processing volume 50–1000 µL per sample
Plate type 96-deep well plate (conical / round bottom)
Processing time Typically 20–40 minutes (reagent dependent)
Heating range 37°C to 125°C
Temperature accuracy ±1.5°C (vendor-stated)
Mixing 8 levels · up to 10 Hz stirring
Magnetic bead recovery Up to 98% (vendor-stated; confirm kit and sample type)
Inter-well variance CV < 3% (vendor-stated; protocol dependent)
Display 7-inch color touchscreen
UV sterilization Built-in (vendor-stated)
Power 24V DC · 100–240V AC adapter included
Battery Optional 24V 5A external battery
USB ports 2× USB
Noise Under 55 dB (vendor-stated)
Dimensions (W × D × H) 210 × 250 × 315 mm
Weight 9 kg
Reagent system Open-system magnetic-bead kits (confirm kit IFU)

Interested in purchasing for your lab?

Share the model, volume, and purchase timeline for your purchase inquiry.

Frequently asked questions

Answers focused on practical buying and implementation questions from lab managers, scientists, and startup founders.

Is the MultiEX 016 a benchtop or portable nucleic acid extractor?

Manufacturer specifications describe a compact benchtop footprint (210 × 250 × 315 mm, 9 kg) with optional 24V 5A external battery for field-deployable setups (vendor-stated).

How many samples per run?

1–16 samples per run per manufacturer specifications.

What plate format does it use?

One 96-deep well plate per run (conical or round bottom).

Can it run on battery power?

24V DC with included adapter; optional 24V 5A external battery is listed for field use (vendor-stated).

What reagent kits are supported?

Open-system design for magnetic-bead kits — confirm compatibility with your kit IFU.

How long does a run take?

Typically 20–40 minutes depending on reagent kit and volumes (manufacturer-stated).

Does it verify setup before a run?

Manufacturer describes an auto-check function for 96-well plate and magnetic rod positioning.

How many programs can be stored?

Manufacturer specifications list storage for more than 500 programs.

What warranty applies?

Use conservative 12-month manufacturer-stated warranty framing unless extended terms are confirmed at purchase.

How do I get pricing?

Submit a purchase inquiry with model, throughput needs, sample types, and timeline — pricing is provided on inquiry, not on this site.

Related buying guides

Continue evaluating workflow fit, model specs, and integration requirements.

Warranty

Manufacturer warranty

The MultiEX 016 includes manufacturer warranty coverage per vendor documentation. Confirm warranty terms when making a purchase inquiry.