Skip to content

Model MultiEX 024L · large-volume extractor

Large-volume automated nucleic acid extraction for diluted and high-input workflows

1–24 samples per run · up to 8 mL per well · elution from 50 µL · reagent strips and strip plates · open-system kits (confirm kit IFU)

  • 50 µL – 8 mL processing volume per sample
  • Up to 160:1 concentration ratio (protocol dependent)
  • 0–3000 RPM rod-sleeve mixing plus linear plate shaking

Key Specifications

Model MultiEX 024L
Throughput 1–24 samples per run
Volume class 50 µL – 8 mL
Footprint 349 × 440 × 388 mm · 32 kg

Why surveillance and liquid-biopsy programs evaluate the MultiEX 024L

Standard bench extractors often target microliter input classes. The MultiEX 024L addresses workflows that need larger starting volumes — manufacturer specifications list up to 8 mL per well and elution volumes as low as 50 µL.

Consumables are reagent strips (one sample) or strip plates (four samples) with magnetic rod sleeves — not generic 96-well plate-only messaging. Confirm your kit IFU and workflow before purchase.

Application framing includes cfDNA, liquid biopsy, wastewater pathogen, and environmental DNA use cases. This is workflow positioning, not diagnostic approval or IVD claims.

  • Throughput-fit automation
  • Magnetic-bead workflow clarity
  • Quote-first purchase path
Workflow fit
Automated bind, wash, and elute on vendor-specified plate formats.
Kit approach
Open-system magnetic-bead kits — confirm kit IFU before validation.
Buying path
Purchase inquiry with throughput, sample type, and volume class details.

More MultiEX 024L photos

  • MultiEX 024L large-volume extractor — alternate product angle
  • MultiEX 024L nucleic acid extraction system — side profile
  • MultiEX 024L automated cfDNA extraction system — full product view
  • MultiEX 024L strip-plate consumable workflow — reagent strip detail
  • MultiEX 024L strip-plate consumable — four-sample strip plate layout

Large input volume

Process up to 8 mL of starting sample per well (vendor-stated) for low-abundance targets.

Low elution volume

Elution from 50 µL supports concentration into downstream reaction volumes.

Advanced mixing

Rotational rod-sleeve mixing 0–3000 RPM plus linear plate shaking (vendor-stated).

Open-system flexibility

Magnetic-bead kits with tunable parameters — confirm kit IFU for your matrix.

Route plasma, cfDNA, and surveillance questions to qualified workflow copy — submit a purchase inquiry for protocol fit and datasheet details.

Key features

  • 1–24 samples per run
  • 50 µL – 8 mL processing volume
  • Up to 8 mL per well
  • Elution from 50 µL
  • Up to 160:1 concentration ratio (protocol dependent)
  • Reagent strips / strip plates + rod sleeves
  • Heating 37°C to 125°C
  • UV + filtered ventilation (HEPA per manufacturer)
  • 10-inch touchscreen · 2× USB
  • 349 × 440 × 388 mm · 32 kg
  • Open-system kits (confirm kit IFU)

Ideal applications

Priority 01

Liquid biopsy / cfDNA

Challenge: Large plasma input with low-abundance targets.

Value: Large-volume and low-elution specs with qualified application framing — not diagnostic claims.

Priority 02

Wastewater surveillance

Challenge: Environmental matrices and pathogen nucleic acid prep.

Value: Workflow positioning for surveillance programs — confirm kit and validation path.

Priority 03

Research & biotech

Challenge: Sample volumes above typical 1 mL extractor limits.

Value: Manufacturer-listed 50 µL – 8 mL volume class and strip consumable format.

What's in the box

Confirm large-volume adapters and optional kits during inquiry.

  • MultiEX 024L extractor
  • 10-inch touchscreen (integrated)
  • Power cord · user manual
  • 8 mL capacity adapter (Optional)
  • cfDNA / wastewater / eDNA kits (Optional)
  • Validation service (Optional)

Technical specs and compatibility

Designed for fast technical review. Final compliance and warranty wording remains marked until approved documentation is published.

Model / SKU MultiEX 024L
Throughput 1–24 samples per run
Processing volume 50 µL – 8 mL per sample
Maximum sample volume Up to 8 mL per well
Minimum elution 50 µL
Concentration ratio Up to 160:1 (protocol dependent)
Consumables Large-volume reagent strips (1 sample), strip plates (4 samples), and magnetic rod sleeves — see manufacturer catalog SKUs below
Catalog — MultiEX-LS1 Large volume reagent strip, 1 sample (DNase/RNase free, non-sterile; confirm IFU)
Catalog — MultiEX-LS4 Large volume reagent plate, 4 samples (DNase/RNase free, non-sterile; confirm IFU)
Catalog — MRS-024L Magnetic rod sleeve for MultiEX 024L (DNase/RNase free, non-sterile; confirm IFU)
Capacity Up to 24 strips or 6 plates
Processing time Typically 20–40 minutes (reagent dependent)
Heating range 37°C to 125°C
Mixing 0–3000 RPM rod sleeves + linear plate shaking
Magnetic bead recovery Up to 98% (vendor-stated; confirm kit)
Contamination control UV · filtered ventilation (HEPA per manufacturer)
Display 10-inch color touchscreen
Power 100–240V AC, 50/60 Hz
Noise Under 60 dB (vendor-stated)
Dimensions (W × D × H) 349 × 440 × 388 mm
Weight 32 kg
Applications (framing) cfDNA · liquid biopsy · wastewater · eDNA (confirm protocol fit)
Reagent system Open-system magnetic-bead kits (confirm kit IFU)

Interested in purchasing for your lab?

Share the model, volume, and purchase timeline for your purchase inquiry.

Frequently asked questions

Answers focused on practical buying and implementation questions from lab managers, scientists, and startup founders.

What is the maximum sample volume per well?

Up to 8 mL per well per manufacturer specifications.

What consumables does it use?

Manufacturer catalog lists MultiEX-LS1 (reagent strip, 1 sample), MultiEX-LS4 (strip plate, 4 samples), and MRS-024L magnetic rod sleeves — confirm IFU before ordering.

What is the processing volume range?

50 µL – 8 mL per sample per manufacturer specifications.

How many samples or consumables fit per run?

1–24 samples per run; manufacturer capacity supports up to 24 reagent strips or 6 strip plates.

Is this for diagnostic use?

Intended-use framing lists research, diagnostic, and biotechnology laboratories — confirm regulatory status and kit IFU separately.

How do I get pricing?

Submit a purchase inquiry — pricing is provided on inquiry, not on this site.

Related buying guides

Continue evaluating workflow fit, model specs, and integration requirements.

Warranty

Manufacturer warranty

The MultiEX 024L includes manufacturer warranty coverage per vendor documentation. Confirm warranty terms when making a purchase inquiry.