Large input volume
Process up to 8 mL of starting sample per well (vendor-stated) for low-abundance targets.
Model MultiEX 024L · large-volume extractor
1–24 samples per run · up to 8 mL per well · elution from 50 µL · reagent strips and strip plates · open-system kits (confirm kit IFU)
Key Specifications
Standard bench extractors often target microliter input classes. The MultiEX 024L addresses workflows that need larger starting volumes — manufacturer specifications list up to 8 mL per well and elution volumes as low as 50 µL.
Consumables are reagent strips (one sample) or strip plates (four samples) with magnetic rod sleeves — not generic 96-well plate-only messaging. Confirm your kit IFU and workflow before purchase.
Application framing includes cfDNA, liquid biopsy, wastewater pathogen, and environmental DNA use cases. This is workflow positioning, not diagnostic approval or IVD claims.
Large input volume
Process up to 8 mL of starting sample per well (vendor-stated) for low-abundance targets.
Low elution volume
Elution from 50 µL supports concentration into downstream reaction volumes.
Advanced mixing
Rotational rod-sleeve mixing 0–3000 RPM plus linear plate shaking (vendor-stated).
Open-system flexibility
Magnetic-bead kits with tunable parameters — confirm kit IFU for your matrix.
Priority 01
Liquid biopsy / cfDNA
Challenge: Large plasma input with low-abundance targets.
Value: Large-volume and low-elution specs with qualified application framing — not diagnostic claims.
Priority 02
Wastewater surveillance
Challenge: Environmental matrices and pathogen nucleic acid prep.
Value: Workflow positioning for surveillance programs — confirm kit and validation path.
Priority 03
Research & biotech
Challenge: Sample volumes above typical 1 mL extractor limits.
Value: Manufacturer-listed 50 µL – 8 mL volume class and strip consumable format.
Confirm large-volume adapters and optional kits during inquiry.
Designed for fast technical review. Final compliance and warranty wording remains marked until approved documentation is published.
| Model / SKU | MultiEX 024L |
|---|---|
| Throughput | 1–24 samples per run |
| Processing volume | 50 µL – 8 mL per sample |
| Maximum sample volume | Up to 8 mL per well |
| Minimum elution | 50 µL |
| Concentration ratio | Up to 160:1 (protocol dependent) |
| Consumables | Large-volume reagent strips (1 sample), strip plates (4 samples), and magnetic rod sleeves — see manufacturer catalog SKUs below |
| Catalog — MultiEX-LS1 | Large volume reagent strip, 1 sample (DNase/RNase free, non-sterile; confirm IFU) |
| Catalog — MultiEX-LS4 | Large volume reagent plate, 4 samples (DNase/RNase free, non-sterile; confirm IFU) |
| Catalog — MRS-024L | Magnetic rod sleeve for MultiEX 024L (DNase/RNase free, non-sterile; confirm IFU) |
| Capacity | Up to 24 strips or 6 plates |
| Processing time | Typically 20–40 minutes (reagent dependent) |
| Heating range | 37°C to 125°C |
| Mixing | 0–3000 RPM rod sleeves + linear plate shaking |
| Magnetic bead recovery | Up to 98% (vendor-stated; confirm kit) |
| Contamination control | UV · filtered ventilation (HEPA per manufacturer) |
| Display | 10-inch color touchscreen |
| Power | 100–240V AC, 50/60 Hz |
| Noise | Under 60 dB (vendor-stated) |
| Dimensions (W × D × H) | 349 × 440 × 388 mm |
| Weight | 32 kg |
| Applications (framing) | cfDNA · liquid biopsy · wastewater · eDNA (confirm protocol fit) |
| Reagent system | Open-system magnetic-bead kits (confirm kit IFU) |
Share the model, volume, and purchase timeline for your purchase inquiry.
Answers focused on practical buying and implementation questions from lab managers, scientists, and startup founders.
Up to 8 mL per well per manufacturer specifications.
Manufacturer catalog lists MultiEX-LS1 (reagent strip, 1 sample), MultiEX-LS4 (strip plate, 4 samples), and MRS-024L magnetic rod sleeves — confirm IFU before ordering.
50 µL – 8 mL per sample per manufacturer specifications.
1–24 samples per run; manufacturer capacity supports up to 24 reagent strips or 6 strip plates.
Intended-use framing lists research, diagnostic, and biotechnology laboratories — confirm regulatory status and kit IFU separately.
Submit a purchase inquiry — pricing is provided on inquiry, not on this site.
Continue evaluating workflow fit, model specs, and integration requirements.
Warranty
The MultiEX 024L includes manufacturer warranty coverage per vendor documentation. Confirm warranty terms when making a purchase inquiry.